    解读环氧防静电地坪涂料对基层的要求
    来源:http://www.jndmzp.com   时间:2015-3-26 11:53:51
    强度要求。基层细石混凝土免除的抗压强度要达到25Mpa以上,与涂料的黏结强度应大于1.5MPa。
    Strength requirements. The compressive strength of base of fine stone concrete exemption to reach more than 25Mpa, and the bonding strength of coating shall be more than 1.5MPa.
    平整度要求。基层的平整度用2M长度靠尺检查,大间隙不得超过2MM。
    Smoothness requirements. Roughness length with 2M base inspection on foot, the maximum clearance shall not be more than 2MM.
    含水率和PH值。基层的含水率应小于4%,PH值小于9。
    Water content and pH value. Base moisture content should be less than 4%, pH value of less than 9.
    表面质量。基层表面应无空鼓,开裂,坑洞,起壳和油污。
    Surface quality. Primary surface should be no hollowing, cracking, potholes, shell and oil.
    防水处理。底层无底下室的基层需要做防水,防潮处理。济南自流平http://www.jndmzp.com/
    Waterproof treatment. The underlying basement base without need to do waterproof, moisture-proof treatment.
    防裂处理。地坪设分割缝以防止面积过大产生温差开裂,应力开裂等。
    Anti cracking processing. Floor set partition seam to prevent the area is too large to produce temperature crack, stress cracking.